<< Back

Converters for electric shavers БИ-0,8М

Converter БИ-0,8М ИЯЕB.667567.011 ТУ У 31.2-22656899-024-2004 is designed to convert direct voltage 50 V into alternating voltage 220 V, frequency 50 Hz, rectangular (meander).

Specifications

ВSupply voltage, V 50+12      -10
ВOutput voltage, V 220±22
ВRated current V, А 0,9
ВOutput voltage frequency, Hz 50±2
ВMaximum long-lasting output power load capacity (at соs φ = 0,85), W 170
ВEfficiency factor, % at least 85
ВProtection level under State Standard GOST 14254-96 IP30
ВClimatic version under State Standard GOST 15150-69 У3.1
ВMechanical loads under State Standard GOST 30631-99 М25
ВWeight, kg max.3
ВDimensions (LхVхН), mm 330х142х67

Inter-carriage high-voltage connection МВС

Inter-carriage high-voltage connection (МВС ИЯЕВ.667512.001 ТУ У 31.2-22656899-027:2005) is designed to connect high-voltage mains of adjacent carriages and provide their electric equipment with high-voltage direct current up to 4 kV or AC voltage with frequency 50 Hz of up to 3,6 kV.

Specifications

Rated voltage, kV 3
Rated current, А 330
Rated transmission capacity, kW 990
Insulation resistance, MOhm at least 100
Testing voltage, kV 10
Protection level under State Standard GOST 14254-96 ІР56
Mechanical loads under State Standard GOST 30631-99 М25

MBС includes:

  • onnection socket MBC-0-Р-095-4000/330 ИЯЕV.301441.013 — 1 pc.
  • dummy receiver MBC-Х-4000 ИЯЕB.301441.016 — 1 pc.
  • Plug with cable MBC-Ш095/4,3-4000/330 ИЯЕB.685621.445 or MBC-Ш095/3,7-4000/330 ИЯЕB.685621.445-01 — 1 pc.
  • Cable console MBC-К-095 ИЯЕB.301568.056 — 1 pc.

Dimensions and weight of MBC components

Component Dimensions, mm Weight, kg
Connection socket 408х254х332 14,0
Dummy receiver 180х225х160 4,0
Plug with cable MBC-Ш095/4,3-4000/330 L=4300 10,5
Plug with cable MBC-Ш095/3,7-4000/330 L=3700 9,5
Cable console 225х240х155 1,8

Low-voltage plug inter-carriage connection

НШМС ИЯЕB.685633.004 ТУ У 31.2-22656899-023-2004 is designed to connect low-voltage electric mains of adjacent railway carriages to ensure emergency lighting in the carriage in case its generator breaks down.

Specifications

Rated voltage, V 50
Allowable load current, А max.25
Resistance value between the ends of two connected НШМС, mOhm max.4
Protection level while connected under State Standard GOST 14254-96 IP56
Mechanical loads under State Standard GOST 30631-99 М25
Climatic version and placement under State Standard GOST 15150-69 У1
Mechanical wear-resistance, cycle at least 2000
Weight, kg max.1,0
Length, mm max.1090

Vestibule light НBB01-25 УХЛ2

Vestibule light НBB01-25 УХЛ2 ИЯЕB.667523.001 ТУ У 31.2-22656899-020-2001 is designed for lighting the vestibules of braking and non-braking ends of the passenger carriage. It is placed on the ceiling of the carriage vestibule.

Specifications

Supply voltage, V 50±12
110±30
Current type direct
Lamp power, W 25(40)
25(40)
Dimensions (LхVхН), mm 160х150х135
Weight, kg 0,475
Mechanical loads under State Standard GOST 30631-99 М25
Climatic version under State Standard GOST 15150-69 УХЛ2
Protection level under State Standard GOST 14254-96 IР23

The type of incandescent lamps for this light is Ж54-25 or Ж110-25 ТУ 16-88 ИКАФ.675.300.002 ТУ. It is acceptable to install lamps Ж54-40 or Ж110-40 ТУ 16-88 ИКАФ.675.300.002 ТУ..

END SIGNAL LIGHT ФСК-У1

End signal light ФСК-У1 ИЯЕB.667526.001 ТУ У 31.2-22656899-021-2004 is designed to mark the tail of the train according to the «Operations Rules» and «Signaling Guidelines» on the railroads of Ukraine.

Specifications

Supply voltage, V 50 ± 12
110 ± 30
Current type direct
Lamp power, W 40, 60 40, 60
Dimensions (LхVхН), mm 247х165х105
Weight, kg 1,750
Mechanical loads under State Standard GOST 30631-99 М25
Climatic version under State Standard GOST 15150-69 У1
Protection level under State Standard GOST 14254-96:
Outside the carriage IР56
Inside the carriage IР23
Type of incandescent lamps Ж54-40-1, Ж54-60,
Ж110-40, Ж110-60-1
ТУ 16-88 ИКАФ.675.300.002
ТУ
Axial lighting force, candles at least 5
Distance of red signal light visibility in clear weather at dark, m at least 1200

END SIGNAL LIGHT ФСК1-У1

End signal light ФСК1-У1 ИЯЕB.667526.014 ТУ У 31.2-22656899-021-2004 is designed to mark the tail of the train according to the «Operations Rules» and «Signaling Guidelines» on the railroads of Ukraine.

Specifications

Supply voltage, V 50 ± 12
110 ± 30
Current type direct
Lamp power, W 40, 60
40, 60
Dimensions (LхVхН), mm 268х220х147
Weight, kg 5
Mechanical loads under State Standard GOST 30631-99 М25
Climatic version under State Standard GOST 15150-69 У1
Protection level under State Standard GOST 14254-96 IР40
Type of incandescent lamps Ж54-40-1, Ж54-60-1,
Ж110-40, Ж110-60-1
ТУ 16-88 ИКАФ.675.300.002 ТУ
Axial lighting force, candles at least 5
Distance of red signal light visibility in clear weather at dark, m at least 1200

LED END SIGNAL LIGHT ФСКС-У1

LED end signal light ФСКС-У1 ИЯЕB.667526.017 ТУ У 31.2-22656899-021-2004 is designed to mark the tail of the train according to the «Operations Rules» and «Signaling Guidelines» on the railroads of Ukraine.

Specifications

Supply voltage, V 50 ± 12
110 ± 30
Current type direct
Power consumption, W max.12
Dimensions (LхVхН), mm 247х165х120
Weight, kg 2
Mechanical loads under State Standard GOST 30631-99 М25
Climatic version under State Standard GOST 15150-69 У1
Protection level under State Standard GOST 14254-96:
Outside the carriage IР56
Inside the carriage IР23
Axial lighting force, candles at least 5
Distance of red signal light visibility in clear weather at dark, m at least 1200

LED END SIGNAL LIGHT ФСКС1-У1

LED end signal light ФСКС1-У1 ИЯЕB.667526.018 ТУ У 31.2-22656899-021-2004 2004 is designed to mark the tail of the train according to the «Operations Rules» and «Signaling Guidelines» on the railroads of Ukraine.

Specifications

Supply voltage, V 50 ± 12
110 ± 30
Current type direct
Power consumption, W max.12
Dimensions (LхVхН), mm 270х270х153
Weight, kg 4
Mechanical loads under State Standard GOST 30631-99 М25
Climatic version under State Standard GOST 15150-69 У1
Protection level under State Standard GOST 14254-96 IР40
Axial lighting force, candles at least 5
Distance of red signal light visibility in clear weather at dark, m at least 1200
14_10.jpg zhd_14_11.jpg zhd_14_12.jpg

14_9.jpg

<< Back