Filter 506
 506

TEXT TECHNICAL INFORMATION

Full name of item, status (in production,
in storage)

Filter 506 (in production)

Force (for which this item is intended)

Ground-forces (armoured equipment)

Destination

Filter O506 is intended for suppression
of high-frequency radio-interference.

Set of units

Filter O506 is made as indivisible item

Principle of operation

Suppression of high-frequency radio-
interference with the aid of inductance-
capacitance filter.

Main functional distinctions (of main
item, of components)

Connection circuit of the filter is single-
wire

Distinctive features

-

Main tactical and technical characteristic

See appendix 25.6

Service:

- teaching;

- transfer of technology to customer;

- giving documentation;

- maintenance (repair, updating) etc.

Post-warranty maintenance and repair.

MAIN TACTICAL AND TECHNICAL CHARACTERISTIC

FILTER 506

1. Input direct voltage - 27 - 29 V

2. Rated current - not more 50 A

3. Insertion attenuation

in the frequency band from 3,75 to 6 MHz - not less 100 dB

4. Design of protection - IP54

5. Mass - not more 1,7 kg

6. Filter 506 is full analog of filter -l, which was in production in the past.